Welcome to the Biamp TCM-XA Installation Manual, your comprehensive guide for installing and configuring the TCM-XA Beamtracking ceiling microphone.
This manual provides detailed instructions for proper installation, ensuring optimal performance and compliance with safety standards like UL 2043.
Designed for use with Biamp Tesira systems, the TCM-XA offers advanced features like Beamtracking technology for superior audio capture in various environments.
1.1 Overview of the TCM-XA Microphone System
The Biamp TCM-XA is a cutting-edge Beamtracking ceiling microphone designed for seamless integration with Biamp Tesira systems.
Part of the Parlé series, it offers superior audio quality with advanced beamforming technology, ensuring precise sound capture in dynamic environments.
Featuring a plenum-rated design, the TCM-XA is ideal for installed audio applications, including meeting rooms, lecture halls, and open spaces.
With PoE+ support and UL 2043 compliance, it meets rigorous safety standards for use in air handling spaces, ensuring reliability and performance.
Its sleek, unobtrusive design blends into ceilings, providing a professional-grade audio solution without compromising aesthetics.
1.2 Importance of Proper Installation
Proper installation of the TCM-XA is critical to ensure optimal performance, safety, and compliance with industry standards.
Incorrect installation can lead to poor audio quality, connectivity issues, or even damage to the device.
Following the guidelines ensures compliance with UL 2043 for air handling spaces and guarantees electrical safety.
Additionally, proper installation maintains warranty validity and prevents potential hazards.
By adhering to the manual’s instructions, users can achieve reliable operation and maximize the microphone’s advanced features.
Pre-Installation Requirements
Verify all components, including the plenum box, microphone, and mounting hardware, are included and undamaged.
Ensure the network and power infrastructure meet PoE requirements for the TCM-XA microphone system.
Confirm compatibility with Tesira systems and check for any necessary firmware updates before proceeding.
Review safety guidelines and ensure compliance with UL 2043 for air handling spaces.
2.1 Checking the Components and Accessories
Before installation, carefully inspect all components of the Biamp TCM-XA system to ensure they are complete and free from damage.
- Plenum Box: Verify the plenum box is intact and suitable for your ceiling type.
- Microphone Unit: Check for any visible damage to the microphone grille or casing.
- Mounting Hardware: Ensure all screws, brackets, and adapters are included and undamaged.
- Power and Network Cables: Confirm the CAT cable and PoE adapter are provided and functional.
Refer to the installation manual or manufacturer’s documentation for a detailed list of included accessories.
2.2 Understanding the Power and Network Requirements
The Biamp TCM-XA requires a Power over Ethernet (PoE) connection, specifically IEEE 802.3at Type 2 Class 4, delivering 30W of power.
- Power: Ensure a PoE-enabled switch or injector is available to meet the 30W requirement.
- Network: Use CAT5e or higher Ethernet cables for reliable data transmission and connectivity to Tesira systems.
- Configuration: Verify network settings, including QoS and VLAN assignments, to prioritize audio traffic and minimize latency.
- Compliance: Adhere to UL 2043 standards if installing in air handling spaces to ensure safety and regulatory compliance.
Proper power and network setup is critical for optimal performance and functionality of the TCM-XA microphone system.
Mounting and Physical Installation
The TCM-XA plenum box is designed for ceiling installation, with options for corner mounting. Proper placement ensures optimal audio performance and compliance with safety standards.
3.1 Plenum Box Installation and Placement
The TCM-XA plenum box is a folded metal enclosure designed for installation above ceilings or ceiling tiles. It ensures secure mounting and optimal audio performance.
Place the plenum box in a centralized location to maximize coverage. Ensure proper alignment with the ceiling grid for a flush finish. Follow UL 2043 guidelines for air handling spaces.
3.2 Corner Installation Options
The TCM-XA can be installed in a corner where two T-bars meet, offering a versatile mounting solution. Position the plenum box securely in the corner, ensuring proper alignment with the ceiling grid for a flush finish. This configuration maintains the microphone’s performance while blending seamlessly into the environment. Adjust the microphone’s orientation to optimize audio capture. Follow all safety guidelines and ensure compliance with local building codes during installation. This method is ideal for spaces with unique architectural features, providing both functionality and aesthetic appeal. Proper placement ensures reliable operation and meets UL 2043 requirements for air handling spaces.
Hardware Setup and Configuration
Connect the TCM-XA to the Tesira system via CAT cable, enabling Beamtracking technology for precise audio capture. Use Tesira software for configuration and optimization.
4.1 Connecting the TCM-XA to the Tesira System
To connect the TCM-XA to the Tesira system, use a single CAT cable for both power and data transmission. Ensure the network is configured correctly.
Connect the microphone to a PoE-enabled switch or Tesira device. Power is delivered via PoE, eliminating the need for a separate power adapter.
Once connected, the TCM-XA will automatically detect and integrate with the Tesira system. Use Tesira software to configure settings and enable Beamtracking technology.
Verify the connection status through the Tesira interface. Proper installation ensures seamless communication and optimal audio performance.
4.2 Configuring the Beamtracking Technology
Configuring the Beamtracking Technology on the TCM-XA ensures dynamic audio pickup based on speaker location. Access the Tesira software to enable and customize this feature. Use the interface to define zones and adjust sensitivity for optimal coverage. The technology automatically tracks and focuses on the speaker’s voice, ensuring clear audio capture. Position the microphone appropriately to maximize performance. Follow the Tesira software guide for detailed configuration steps. Proper setup enhances audio quality and minimizes background noise. This feature is a key advantage of the TCM-XA, providing adaptive audio solutions for various environments. Ensure all settings align with your specific application needs for best results.
Network and Power Configuration
Configure the TCM-XA using PoE (Power over Ethernet) for seamless network integration. Connect to Biamp Tesira systems for efficient setup and reliable performance.
5.1 Setting Up PoE (Power over Ethernet)
Power over Ethernet (PoE) simplifies the TCM-XA installation by delivering power and data through a single Ethernet cable. Ensure your network switch supports PoE (IEEE 802.3at Type 2, Class 4) and can provide 30W of power. Connect the TCM-XA to the switch using a CAT5e or higher Ethernet cable. Enable PoE on the switch port and verify the microphone powers on. If the device does not power up, check the PoE configuration or consider using an external PoE injector. Use the Tesira software to confirm the connection and configure settings as needed.
5.2 Integrating with Tesira Software
Integrating the Biamp TCM-XA with Tesira software is essential for optimal performance. Connect the TCM-XA to a PoE-enabled network switch, ensuring it supports IEEE 802.3at Type 2, Class 4, providing 30W of power. Open the Tesira software and navigate to the device discovery section to automatically detect the TCM-XA. Once detected, configure settings like audio levels and Beamtracking parameters. Check for firmware updates and install them to maintain compatibility. Ensure network settings, such as IP addresses, are correctly configured for communication. Secure the network to prevent unauthorized access. Test the microphone to confirm proper integration and functionality. For any issues, refer to Biamp’s troubleshooting guides or support resources.
Safety and Compliance
Ensure compliance with UL 2043 for air handling spaces and proper grounding to maintain electrical safety and prevent hazards during installation and operation of the TCM-XA.
6.1 UL 2043 Compliance for Air Handling Spaces
The Biamp TCM-XA is UL 2043 compliant, making it suitable for installation in air handling spaces such as plenums and dropped ceilings.
UL 2043 certification ensures the device meets strict safety standards for heat release and smoke generation, critical for maintaining air quality and safety in HVAC systems.
Proper installation in accordance with UL 2043 guidelines prevents potential fire hazards and ensures compliance with local building codes and regulations.
The TCM-XA’s plenum-rated design allows for safe and reliable operation in environments where air circulation and fire safety are paramount.
Always follow the manual’s instructions to maintain compliance and ensure the system functions safely and efficiently in its intended environment.
6.2 Ensuring Proper Grounding and Electrical Safety
Proper grounding is essential for the safe and reliable operation of the Biamp TCM-XA microphone system.
Ensure all electrical connections, including the microphone and plenum box, are securely grounded to prevent electrical noise and ensure safety.
Use shielded CAT cables for connections to minimize interference and maintain signal integrity.
Verify that the PoE (Power over Ethernet) switch or injector provides the required 30W of power to the TCM-XA.
Disconnect power before performing any maintenance or repairs to avoid electrical shock or damage.
Always follow local electrical codes and safety standards when installing the system.
Grounding ensures optimal performance and protects against potential electrical hazards.
Troubleshooting Common Issues
This section provides solutions for common issues with the Biamp TCM-XA, including connectivity problems, audio quality, and software configuration. Refer to the Tesira software for diagnostic tools and troubleshooting guides.
7.1 Diagnosing Connectivity Problems
Connectivity issues with the Biamp TCM-XA can often be resolved by checking the Power over Ethernet (PoE) connection and ensuring the network cable is securely connected. Verify that the PoE switch is functioning correctly and delivers the required 30W of power. If using a PoE injector, ensure it is compatible with the TCM-XA. Check the network settings and IP configuration to confirm proper communication with the Tesira system. Use the Tesira software to monitor device status and diagnose connection problems. If issues persist, inspect the Ethernet cable for damage or loose connections. Ensure the TCM-XA is recognized by the Tesira system for optimal performance.
7.2 Resolving Audio Quality Issues
Audio quality issues with the Biamp TCM-XA can often be addressed by adjusting the Beamtracking settings in the Tesira software. Ensure the microphone is placed in an optimal location, avoiding areas with high reverberation or background noise. Check for firmware updates and install the latest version to ensure compatibility and performance. Verify that the gain settings are properly configured to avoid distortion or low volume. If echo or feedback occurs, adjust the acoustic echo cancellation settings. Ensure the microphone is not placed near HVAC vents or other noise sources. Regularly inspect the microphone for dust or debris that may affect performance. Proper configuration and environmental adjustments can significantly improve audio clarity and consistency.